UALT-3/8-100 3/8" UL CSA LIQUID TIGHT STEEL

*Product images are for illustrative purposes only and may differ from the actual product.

UALT-3/8-100 3/8" UL CSA LIQUID TIGHT STEEL

Part #: UALT-3/8-100
3/8" UL CSA LIQUID TIGHT STEEL
Construction
Category Jacket Description • Flexible PVC • Resistant to Oils and Mild Acids • Flame Retardant • Sunlight Resistant (UV) • Marked HD for “Heavy-Duty”
Applications Listed and marked for Direct Burial and in Poured Concrete • For containment of 1000 volt and lower potential circuits Suitable as a grounding conductor when used for circuits rated up to 20A for the 3/8 & 1/2 inch trade sizes and 60A for the 3/4 through 1-1/4 inch trade sizes in lengths six feet or less per NEC Article 250.118(6). Larger sizes require separate grounding conductor. • • Installations in hazardous (classi􀄄ed) locations: • Class I Div. 2: Article 501.10 (B)(2) & 501.30 (B) • Class II Div. 1: Article 502.10 (A)(2) & 502.30 (B) Div. 2: 502.10 (B)(2) • Class III Div. 1: Article 503.10 (A)(3) & 503.30 (B) Div. 2: 503.10 (B)
Applications Listed and marked for Direct Burial and in Poured Concrete • For containment of 1000 volt and lower potential circuits Suitable as a grounding conductor when used for circuits rated up to 20A for the 3/8 & 1/2 inch trade sizes and 60A for the 3/4 through 1-1/4 inch trade sizes in lengths six feet or less per NEC Article 250.118(6). Larger sizes require separate grounding conductor. • • Installations in hazardous (classi􀄄ed) locations: • Class I Div. 2: Article 501.10 (B)(2) & 501.30 (B) • Class II Div. 1: Article 502.10 (A)(2) & 502.30 (B) Div. 2: 502.10 (B)(2) • Class III Div. 1: Article 503.10 (A)(3) & 503.30 (B) Div. 2: 503.10 (B)
Bend Radius 4
Category Fittings and Accessories
Category Jacket Description • Flexible PVC • Resistant to Oils and Mild Acids • Flame Retardant • Sunlight Resistant (UV) • Marked HD for “Heavy-Duty”
Conduit Size 3/8
CSA Certified Yes
Jacket Material Flexible PVC
Outside Diameter Inches 0.71
Package Qty 100 FT REEL
Product Short Description • Inner Core of Hot Dipped Galvanized Steel • Manufacturer Part# Type LA
Show Sku on Part Number Table yes
Sortorder 0
UL Rating Yes

Questions & Answers

Ask a Question

Part Number Table

Part # Bend Radius Outside Diameter Inches Package Qty Conduit Size
UALT-3/8-100 4 0.71 100 FT REEL 3/8
UALT-1/2-100 5 0.84 100 FT REEL 1/2
UALT-3/4-100 6 1.03 100 FT REEL 3/4
UALT-1-100 12 1.315 100 FT REEL 1
UALT-2-1/2-25 30 2.875 25 FT REEL 2 1/2
UALT-3-25 36 3.5 25 FT REEL 3
UALT-3-1/2-25 43 4 25 FT REEL 3 1/2
UALT-4-25 52 4.5 25 FT REEL 4
UALT-1-1/4-50 15 1.66 50 FT REEL 1 1/4
UALT-1-1/2-50 17 1.9 50 FT REEL 1 1/2
UALT-2-50 22 2.375 50 FT REEL 2