CL3R/CMR Non-shielded 16 AWG & 18 AWG

*Product images are for illustrative purposes only and may differ from the actual product.

CL3R/CMR Non-shielded 16 AWG & 18 AWG 300V

CL3R - Nonshielded Conductors
PVC Insulation & Jacket
300 Volt
18 AWG & 16 AWG

Construction
Category Conductor Description Stranded bare copper to ASTM B-3, B-8, and B-286
Category Insulation Description Color coded Polyvinyl Chloride (PVC)
Category Jacket Description Gray, Polyvinyl Chloride (PVC) Includes ripcord
  • Power limited control circuits
  • Wiring of the following systems: Intercom, Security, & Audio
  • Suggested Voltage Rating: 300 Volts
  • NEC Article 725 Type CL3R
  • CSA CMG FT-4

Questions & Answers

Ask a Question

Part Number Table

Part # Gauge Conductors Insulation Thickness Jacket Thickness Outside Diameter Inches Material Weight (Lbs./M') Material Weight (KG/KM)
DS91802 18 2 0.009 0.015 0.154 17.1 25
DS91803 18 3 0.009 0.015 0.166 23.6 35
DS91804 18 4 0.009 0.015 0.187 28.9 43
DS91806 18 6 0.009 0.015 0.225 42 62
DS91808 18 8 0.009 0.015 0.245 56.4 83
DS91810 18 10 0.009 0.015 0.27 69 102
DS91812 18 12 0.009 0.015 0.29 84 125
DS91602 16 2 0.01 0.015 0.178 25 37
DS91603 16 3 0.01 0.015 0.196 39 58
DS91604 16 4 0.01 0.015 0.209 45.1 67

Note: The data shown is approximate and subject to standard industry and manufacturer tolerances.