15kV - EPR Insulation, PVC Jacket - COMPRESSED

*Product images are for illustrative purposes only and may differ from the actual product.

15kV - EPR Insulation, PVC Jacket - COMPRESSED

Part #: MVA350001-COMPRESSED
x

Please select all above options before adding to cart.

Construction
Category Aluminum
Category Features • Rated at 105˚C • High Speed low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions
Category Conductor Description 2 AWG thru 1000 kcmil 1350 aluminum compressed Class B strand
Category Insulation Description Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers
Category Jacket Description Low-friction, lead-free, flame-retardant, moisture and sunlight-resistant Polyvinyl Chloride (PVC)
  • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5)
  • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8-13 (AEIC CS8-20, Optional) • CSA C68.10 • CSA C22.2 No. 230 Type TC-ER (Sizes 1/0 AWG and larger) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant

Questions & Answers

Ask a Question

Part Number Table

Part # Insulation Diameter Min Insulation Diameter Max Gauge Conductor Diameter Jacket Thickness Outside Diameter Inches
MVA335001-COMPRESSED 1.07 1.155 350 0.66 0.08 1.41
MVA31/001-COMPRESSED 0.745 0.83 1 0.32 0.08 1.06
MVA33/001-COMPRESSED 0.865 0.955 3 0.46 0.08 1.19
MVA34/001-COMPRESSED 0.92 1.005 4 0.51 0.08 1.25
MVA350001-COMPRESSED 1.19 1.275 500 0.79 0.08 1.54
MVA32/001-COMPRESSED 0.71 0.8 2 0.28 0.08 1.02